Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments (Administrator) |
---|---|---|---|---|---|
ACL.01 | Laboratory test: Measurement of airborne sound reduction index for Rw. Range: Rw ≤ 72 dB | ISO 10140-1:2021 (except annexes J and K); ISO 10140-2: 2021; ISO 10140-4:2021; ISO 717-1:2020 | Building elements | EN 1793-2:2018, EN 1793-3:1997 (only applicable to noise barriers intended for road traffic); EN 16272-2:2012, EN 16272-3-1:2012 (only applicable to noise barriers intended for railway) | |
ACL.02 | Laboratory test: Measurement of sound absorption in a reverberation room | NP EN ISO 354:2007 | Building acoustics | EN ISO 11654:1997 (applicable to flat objects); EN 1793-1:2017, EN 1793-3:1997 (only applicable to noise barriers intended for road traffic); EN 16272-1:2023, EN 16272-3-1:2023 (only applicable to noise barriers intended for railway) | |
ACL.03 | Laboratory test: Determination of impact sound insulation index, Ln,w. Range Ln,w ≥ 25 dB | ISO 10140-3:2021; ISO 10140-4:2021; ISO 717-2:2020 | Building acoustics | Range: Ln,w ≥ 25 dB | |
ACL.06 | Laboratory measurement of the reduction of the transmitted impact noise by floor coverings ∆Lw. Range: ∆Lw ≤ 50 dB | ISO 10140-1:2021; ISO 10140-3:2021; ISO 10140-4:2021; ISO 717-2:2020 | Building acoustics | Range: ∆Lw ≤ 50 dB | |
VBR.02 | Characterisation of anti-vibration mounts | Internal procedure VBR.02.IE.01 (version no. 3 of May 2020) | Anti-vibration mounts for ceilings |