Itecons has at its disposal modern facilities designed to carry out a variety of tests including physical and mechanical accredited tests in accordance with the latest national and European standards. We perform resistance tests, durability studies, property verification and fault analysis.
Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments (Administrator) |
---|---|---|---|---|---|
OEF.09 | Determination of the operating forces of shutters and blinds | EN 13527:1999; Internal Procedure OEF.09.IE.01 (version no. 4 of May 2020) | Shutters and blinds | ||
OEF.10 | Determination of the wind load resistance of shutters | EN 1932:2013 (except point 7 and 8.2); EN 13659:2004+A1:2008 | Shutters | ||
OEF.11 | Static tests on balcony handrails - horizontal static force | NP 4491:2009 (section 4.2) | Balcony handrails | ||
OEF.12 | Static tests on balcony handrails - vertical static force | NP 4491:2009 (section 4.3) | Balcony handrails | ||
OEF.13 | Dynamic tests on balcony handrails - shock with hard body | NP 4491:2009 (procedure 5.3.1) | Balcony handrails | ||
OEF.14 | Dynamic tests on balcony handrails - shock with soft body | NP 4491:2009 (procedure 5.3.2) | Rails for buildings | ||
OEF.25 | Determination of the resistance to wind load of industrial, commercial and garage doors and gates | EN 12424:2000, EN 12444:2000 | Industrial, commercial and garage doors and gates | ||
OEF.26 | Determination of the mechanical durability of industrial, commercial and garage doors and gates | EN 12604:2000, EN 12605:2000 | Industrial, commercial and garage doors and gates | ||
OEF.34 | Static tests on balcony handrails - horizontal static force | UNE 85238:1991 (sections 9.1.1, 9.1.2 e 9.3) | Balcony handrails | ||
OEF.35 | Static tests on balcony handrails - vertical static force | UNE 85238:1991 (section 9.1.3) | Balcony handrails | ||
OEF.36 | Dynamic tests on balcony handrails - shock with hard body | UNE 85238:1991 (section 9.2.3.2.3) | Balcony handrails | ||
OEF.37 | Dynamic tests on balcony handrails - shock with soft body | UNE 85238:1991 (section 9.2.3.2.2) | Balcony handrails | ||
OEF.38 | Static tests on balcony handrails - horizontal static force | NF P01-013 (sections 2.2.1 e 2.2.2) | Balcony handrails | ||
OEF.39 | Static tests on balcony handrails - vertical static force | NF P01-013 (section 2.2.3) | Balcony handrails | ||
OEF.40 | Dynamic tests on balcony handrails - shock with hard body | NF P01-013 (section 2.3) | Balcony handrails |