Energy performance, environmental impact and safety are increasingly more relevant when choosing construction material and equipment. Itecons has facilities to carry out tests catering to these concerns.
Reference | Designation/Description | Accredited assay |
Reference standards |
Product/ Material |
Comments (Administrator) |
---|---|---|---|---|---|
CXL.01 | Determination of the air permeability | EN 1026:2016, EN 12207:2016 | Doors and windows | ||
CXL.16 | Determination of the thermal transmittance of doors and windows by hot box method | EN ISO 12567-1:2010, EN ISO 12567-1:2010/AC:2010 | Doors and windows | Range: Doors and windows less than or equal to 2m x 2m | |
CXL.17 | Determination of the thermal transmittance of doors and windows | ISO 10077-1:2017, ISO 10077-2:2017 | Doors and windows | ||
CXL.21 | Determination of the air permeability of doors, windows and curtain walling | ASTM E283 / E283M | Doors, windows and curtain walling | ||
EQP.02 | Residential space heating appliance | NP EN 14785:2008* (sections 4, 5 (except section 5.9), 6, 7, 8); fuel characterization tests according to Annex B of EN 16510-1: 2022 | Residential space heating appliance, fired by wood pellets with nominal heat output up to 50 kW | The normative document indicated with * is void, and its tecnical validity is not in question. | |
EQP.06 | Determination of performance and energy consumption | EN 16147; Regulation (EU) No. 812/2013 of 18 February 2013 and Regulation (EU) No. 814/2013 of 2 August 2013 | Domestic water heat pumps with electrically driven compressors | The test can be performed according to EN 16147:2011*; EN 16147:2011/AC:2011* or EN 16147:2017; EN 16147:2017/AC:2017 (except section 7.11). The normative document indicated with * is void, and its tecnical validity is not in question. | |
EQP.10 | Determination of useful storage volume and heat loss | EN 12897:2006* (sections 6.2.2 and 6.2.7 and Annex B); Regulation (EU) No. 812/2013 of 18 February 2013 (point 2 of Annex II and Annex IX) | Hot water tanks | The normative document indicated with * is void, and its tecnical validity is not in question. | |
EQP.11 | Performance acceptance test of hydraulic pumps (fluid equated to water) | ISO 9906:2012 | Centrifugal and axial pumps | ||
EQP.14 | Storage volume and heat loss determination of hot water tanks | EN 15332:2007 - ponto 5.4; Regulamento Delegado (UE) Nº 812/2013 | Reservatórios de água quente | ||
EQP.15 | Electrical Safety | EN 60335-1, IEC 60335-1 (except section 29.2 and Annex N); EN 60335-2-40, IEC 60335-2-40, EN IEC 60335-2-40 | Heat pumps for DHW | EN 60335-1:2012, EN 60335-1:2012/AC:2014, EN 60335-1:2012/A11:2014, EN 60335-1:2012/A13:2017, EN 60335-1:2012/A1:2019, EN 60335-1:2012/A2:2019, EN 60335-1:2012/A14:2019, EN 60335-1:2012/A15:2021, EN 60335-1:2012/A16:2023 IEC 60335-1:2020, IEC 60335-1:2020/COR1:2021, (exceto secção 29.2 e anexo N / except section 29.2 and Annex N) EN IEC 60335-2-40:2023, EN IEC 60335-2-40:2023/A11:2023 IEC 60335-2-40:2022 | |
EQP.16 | Performance tests | EN 16510-1:2022 | Residential solid fuel burning appliances | ||
EQP.17 | Determination of the sound power level | EN 12102-2:2019 | Heat pumps for domestic hot water | ||
EQP.20 | Performance tests - Mechanically by wood pellets fed roomheaters, inset appliances and cookers | EN 16510-1:2022; EN 16510-2-6:2022 | |||
EQP.21 | Performance tests - Roomheaters | ||||
EQP.22 | Performance tests - Inset appliances including open fires |